Home / Guides / EU Machinery Regulation

Risk assessment under Machinery Regulation 2023/1230

Every machine placed on the EU market from 20 January 2027 needs a risk assessment that shows which requirements of Annex III apply and how each one is met. This guide sets out the five steps the Regulation requires, what is new compared with the Directive, what goes in the technical file, a worked example and common mistakes.

Written by Proxom Engineering Ltd, a UK mechanical design engineering company. Checked against Regulation (EU) 2023/1230 on EUR-Lex on 11 November 2026. Quotations are paraphrased. General information, not legal advice.

The short answer

  1. The manufacturer must ensure that a risk assessment is carried out to find out which essential health and safety requirements (EHSRs) of Annex III apply, and then design and build the machine to eliminate hazards or minimise the risks (Annex III, General Principles, point 1).
  2. The method is an iterative process of five steps: determine the limits (intended use and reasonably foreseeable misuse), identify hazards, estimate the risks, evaluate them, and eliminate or reduce them in the order of section 1.1.2(b): safe design first, then guards and protective devices, then information on residual risks.
  3. The five steps are the same as under Directive 2006/42/EC. What is new are two added paragraphs (hazards from self-evolving behaviour over the lifecycle, and risks from interactions between machines forming an assembly) and new or extended requirements to assess, above all protection against corruption (1.1.9) and safety and reliability of control systems (1.2.1).
  4. You must look at the whole of Annex III to be sure you meet every relevant requirement (General Principles, point 4). The usual way to show that is a section-by-section EHSR applicability table.
  5. The result goes into the technical file: Annex IV, Part A, point (b) asks for the risk assessment documentation, including the list of applicable EHSRs and the protective measures for each, with the residual risks where appropriate. It is kept for at least 10 years (Article 10(3)).
  6. No method is prescribed. EN ISO 12100 is the common way to do it; check its citation status under the Regulation in the Official Journal before you rely on it for a presumption of conformity (Article 20).

What the Regulation says

Annex III, Part B, General Principles, point 1: the manufacturer of machinery or a related product shall ensure that a risk assessment is carried out in order to determine the essential health and safety requirements which apply to it. The machine shall then be designed and constructed to eliminate hazards or, if that is not possible, to minimise all relevant risks, taking into account the results of the risk assessment.

Point 2: the obligations of the EHSRs apply only when the corresponding hazard exists for the machine when it is used under the conditions foreseen by the manufacturer or in foreseeable abnormal situations. The principles of safety integration (1.1.2), the marking requirements (1.7.3) and the instructions (1.7.4) apply in all cases.

Point 3: the EHSRs are mandatory; where the state of the art does not allow their objectives to be met, the machine shall as far as possible be designed and constructed to approach them. Point 4: it is essential to examine the whole of Annex III; chapter 1 applies to all machinery, and the other chapters according to the results of the risk assessment. Point 5: the same principles apply to partly completed machinery.

The five steps, and what to record

The Regulation calls it an iterative process of risk assessment and risk reduction: after each protective measure, check whether it introduces new hazards and go round again.

StepWhat the Regulation requiresWhat to recordISO 12100 clause
(a) LimitsDetermine the limits of the machinery, including the intended use and any reasonably foreseeable misuse.Use, space, time and other limits: who uses it (trained operator, maintenance, cleaner, non-professional?), operating modes, life phases from transport to dismantling, materials processed, misuse that follows from readily predictable human behaviour (Annex III, Part A (i)).5.3
(b) HazardsIdentify the hazards the machinery may generate and the associated hazardous situations.A hazard list per life phase and task: mechanical, electrical, thermal, noise, vibration, radiation, materials, ergonomic, environment, and now software and connection hazards. Name the hazardous situation, not only the hazard.5.4
(c) EstimateEstimate the risks, taking into account the severity of the possible injury or damage to health and the probability of its occurrence.For each hazardous situation: severity, exposure, probability of the hazardous event, possibility to avoid or limit harm. Any consistent method is acceptable (risk graph, matrix, scoring); write down the scale you used.5.5
(d) EvaluateEvaluate the risks, with a view to determining whether risk reduction is required, in accordance with the objective of the Regulation.A decision per risk: reduction needed or adequately reduced, and why. Compare with the state of the art and with the relevant type-C standard where one exists.5.6
(e) ReduceEliminate the hazards or reduce the risks by applying protective measures in the order of priority of section 1.1.2(b).The measure chosen, its type (inherently safe design, safeguarding or complementary measure, information for use), the EHSR it meets, the standard applied, and the residual risk. Then repeat from step (b) for hazards the measure itself introduces.6

Clause numbers refer to EN ISO 12100:2010. The standard is a method, not a legal requirement.

The order of protective measures (section 1.1.2(b))

In selecting the most appropriate methods, the manufacturer must apply these principles in this order:

  1. Eliminate hazards or minimise risks by design: inherently safe design and construction (lower force, speed or energy; remove the pinch point; avoid the need to reach in).
  2. Take the necessary protective measures for risks that cannot be eliminated, for example guards, protective devices and the safety functions behind them, plus complementary measures such as emergency stop.
  3. Inform users of the residual risks due to any shortcomings of the protective measures adopted, say whether particular training is required and specify any need for personal protective equipment.

What is new compared with the Directive

TopicWhat changedWhat to do in your assessment
Self-evolving behaviourNew paragraph in General Principles, point 1: include hazards that might arise during the lifecycle and are foreseeable at the time of placing on the market as an intended evolution of fully or partially self-evolving behaviour or logic of machines designed to operate with varying levels of autonomy.Only relevant if the machine learns or adapts its behaviour. Then assess the limits of that evolution, not only the behaviour on delivery. Safety components, and machinery with embedded systems, with fully or partially self-evolving behaviour using machine learning approaches ensuring safety functions are in Annex I, Part A (points 5 and 6), so a notified body is involved.
Assemblies of machinesNew paragraph: include risks resulting from interactions between machines arranged and controlled to function as an integral whole, forming machinery under Article 3, point 1(d).For a line or cell, assess the interfaces: shared stops, transfer points, start-up and restart across machines, zones and access. Supplier assessments of each machine do not cover the interactions.
Protection against corruptionNew section 1.1.9: the machine must be protected against accidental or intentional corruption of safety-critical hardware, software and data, including through connection to other devices.Add hazards from laptops, remote access, network connections and parameter changes to the hazard list. See the corruption protection guide.
Control systemsSection 1.2.1 extended: control systems must withstand the intended operating stresses and external influences, now including reasonably foreseeable malicious attempts by third parties leading to a hazardous situation.Link each safety function to the hazard it reduces, its required performance (for example PL to EN ISO 13849-1) and its validation.
Autonomous mobile machineryChapter 3 adds requirements for autonomous mobile machinery and its supervisory function.Assess the movement zone, detection of persons and the supervisor's means to stop and restart the machine. Describe sensor-based safety under Annex IV point (n).

What goes in the technical file

Annex IV, Part A, point (b) asks for the documentation on risk assessment demonstrating the procedure carried out, including:

In practice that is three documents that refer to each other: the risk assessment report (limits, hazard list, estimation, evaluation, measures, residual risks), the EHSR applicability table (every Annex III section marked applies or not applicable, with the reason and the measure or standard), and the instructions, which carry the residual risks to the user. Annex IV, Part B, point (b) asks for similar documentation for partly completed machinery: the list of applicable EHSRs and the protective measures implemented to eliminate identified hazards or reduce risks, with residual risks where appropriate. See our Annex IV technical file guide.

Worked example: a robot palletising cell

Five rows from the risk assessment of a fictional robot palletising cell for sealed cartons, not in Annex I (module A).

Hazardous situationEstimateMeasure (type)Annex IIIResidual risk
Operator walks into the cell to clear a jammed carton while the robot movesSeverity: serious, irreversible. Probability: likely (daily jams).Perimeter fence to reach distances; interlocked access door with guard locking, robot stopped before the door opens (safeguarding)1.3.7, 1.4.2.2Low. Instructions: clear jams only through the door.
Person enters through the pallet exit opening behind a leaving palletSeverity: serious, irreversible. Probability: possible.Light curtain with muting for the pallet only, processed by the safety PLC to PL d (safeguarding)1.2.1, 1.3.7Low. Muting zone set and locked at commissioning.
Safety configuration changed with a laptop on site, muting zone enlargedSeverity: serious, irreversible. Probability: possible (output pressure).Password-protected safety PLC, checksum recorded in the technical file, change log enabled; programming port sealed (design and safeguarding)1.1.9, 1.2.1Low. Residual: instructions warn that changes void the declaration.
Maintenance technician reaches the gripper during tool changeSeverity: moderate. Probability: possible.Tool change position at waist height outside the robot path (inherently safe design); energy isolation point lockable (complementary measure)1.1.6, 1.6.3Low. Lockout procedure in the maintenance instructions.
Carton dust and noise near the operator stationSeverity: slight. Probability: likely.Not significant after measurement: emission values declared in the instructions1.5.8, 1.7.4.2Noise emission figures in the instructions (1.7.4.2).

Fictional example with simplified wording. Section numbers show where each measure is recorded in the EHSR table; check every section against the official text for your own machine.

Seven common mistakes

  1. A hazard list without hazardous situations. “Crushing” is not enough: say who, doing what, in which mode and life phase.
  2. Only normal operation. Setting, cleaning, fault finding, maintenance, transport and dismantling are where most accidents happen, and they are within the limits you must define.
  3. Starting with warnings. Section 1.1.2(b) sets the order: design first, then safeguarding, then information. A warning sign is not a substitute for a guard you could fit.
  4. No link from risk to EHSR. Annex IV (b) asks for the measures that meet each applicable EHSR. Map every measure to its Annex III section and mark the sections that do not apply, with a reason.
  5. Residual risks that never reach the instructions. Every residual risk you accept must be carried into the instructions and, where needed, the markings (1.1.2(b)(iii), 1.7.4).
  6. A Directive-era assessment copied unchanged. From 20 January 2027 the declaration refers to the Regulation, so check the assessment against Annex III, especially 1.1.9 and 1.2.1, and the new technical file points (m) and (n).
  7. No date, version or author. The assessment is evidence in the technical file; it must show which machine version and which design state it covers.

Questions

Is a risk assessment mandatory under Regulation 2023/1230?

Yes. Annex III, General Principles, point 1 requires the manufacturer of machinery or a related product to ensure that a risk assessment is carried out to determine the essential health and safety requirements which apply. The technical documentation must contain the risk assessment documentation (Annex IV, Part A, point (b)), and the manufacturer must draw up that documentation before placing the machine on the market or putting it into service (Article 10(2)).

Is EN ISO 12100 mandatory?

No. Standards are voluntary. EN ISO 12100 is the usual method and its steps match the Regulation's. Applying a harmonised standard whose reference is published in the Official Journal under Regulation 2023/1230 gives a presumption of conformity with the requirements it covers (Article 20). Check the current list of references in the Official Journal; the list under the Directive does not carry over automatically. As at 12 November 2026 no harmonised standards had been cited in the OJ under Regulation (EU) 2023/1230 (the Commission expects a first list); until then list standards as other technical specifications with their date (Annex IV, Part A, point (f)).

What changed compared with the Machinery Directive?

The five steps and the order of priority are the same. The Regulation adds two paragraphs to General Principles point 1 (hazards from intended self-evolving behaviour over the lifecycle, and risks from interactions between machines forming an assembly), new or extended Annex III sections such as 1.1.9 (protection against corruption) and 1.2.1 (control systems, including foreseeable malicious attempts), and requirements for autonomous mobile machinery in chapter 3. See our Regulation vs Directive comparison.

Do I need a new risk assessment for a machine design I already sell?

Not necessarily a new one, but a reviewed one. Units placed on the market from 20 January 2027 need an EU declaration of conformity under the Regulation, which states that the applicable Annex III requirements are met (Article 21). Review the existing assessment against Annex III, add what is new for your machine, and update the technical file. Units placed on the market in conformity with the Directive before that date can still be made available (Article 52(1)); see our Article 52 guide.

Does partly completed machinery need a risk assessment?

Yes. The General Principles apply to the risk assessment of partly completed machinery too (point 5), and Annex IV, Part B, point (b) asks for the risk assessment documentation, including the list of EHSRs that apply to it. The declaration of incorporation states which EHSRs are applied and fulfilled; requirements that can only be met at incorporation are left to the final machine's manufacturer. See our declaration of incorporation guide.

Can someone else carry out the risk assessment for me?

Yes. The Regulation says the manufacturer shall ensure that a risk assessment is carried out, so a consultant or an integrator can do the work. The manufacturer stays responsible for it and for the declaration of conformity, which it issues on its sole responsibility.

Does the risk assessment go into the declaration of conformity?

No. The declaration states conformity with the applicable requirements and lists the standards or specifications applied. The risk assessment stays in the technical file, which you must be able to make available to market surveillance authorities on request. See what a declaration must contain.

What if a requirement cannot be fully met with today's technology?

The EHSRs are mandatory, but where the state of the art does not allow their objectives to be met, the machine must, as far as possible, be designed and built to approach those objectives (General Principles, point 3). Record in the assessment why the objective cannot be fully met and what you did instead.

Related guides: Annex III requirements list · Technical file under Annex IV · Regulation vs Directive · Protection against corruption · Declaration of conformity contents · Conformity assessment (Annex I) · Substantial modification (Article 18) · Declaration of incorporation · Does it apply to UK builders?. We sell to businesses only; see Terms. Always verify against the official text of Regulation (EU) 2023/1230 on EUR-Lex.